Mitsubishi integration that reaches the systems other tools can't.
Connect Mitsubishi Electric MELSEC to your ERP, historian, maintenance + AI in real-time. Read device memory and machine-state at the edge over SLMP or OPC-UA, no SCADA required, without touching control logic.
+
Live demo · Claude querying Mitsubishi + ops via Rayven MCP
Trusted by 240+ teams across Australia + globally
Mitsubishi is brilliant at what it does. Useless at everything else your data + AI needs to touch.
Device maps live in GX Works, line data is trapped on CC-Link IE, maintenance reacts after downtime, and AI models never see live MELSEC device memory across the estate.
The integration tool you've already tried probably can't fix it.
SaaS-to-SaaS. Useful, until it isn't.
Connectors for Mitsubishi, Slack + a thousand other SaaS apps. Cheap + fast for the easy half of integration. Where they hit a wall:
- ERP that needs live device values and run state per line across an APAC estate
- Historian and data-warehouse targets that should hold every MELSEC device at full rate
- CMMS that should raise a work order when a MELSEC error code or alarm device fires
- OEE and predictive-maintenance models needing live cycle counts, states and reject data
- CC-Link IE networks whose device data never leaves the control cell for the enterprise
SCADA, historians, ERP, IoT + AI. One platform.
The integration platform built for what other tools can't (or won't) reach - plus an AI data fabric, MCP server + app builder layered on top.
- Mitsubishi + every SCADA, historian and ERP system
- OPC-UA, EtherNet/IP, Modbus, PROFINET, S7 + custom-built connectors.
- Files, legacy SQL, FTP + custom-built connectors
- Real-time bidirectional sync, tier-aware + rate-limit-safe
- AI Data Fabric, MCP, automation + custom apps included
Mitsubishi + Rayven: AI, automation + tools that reach every system you run.
5 examples of what Rayven customers run on Mitsubishi + integrated systems. Built in weeks, not months.
MELSEC device memory streams to the fabric
Rayven reads MELSEC data registers, link devices and I/O over the SLMP and MC protocols or OPC-UA, then streams them into a real-time Industrial AI Data Fabric with historian and ERP context. No GX Works export, no SCADA layer required.
Error code raises the work order
A MELSEC error code or alarm device opens a work order in CMMS automatically, carrying the asset, line and live machine-state so the technician arrives knowing the fault, not just the stoppage.
Line output posts to ERP
Cycle counts, run state and reject totals read from MELSEC devices post to ERP in real-time, so planning and finance see live output instead of a shift-end tally keyed by hand.
Cell data reaches the enterprise
Device data riding CC-Link IE Field inside the control cell reads out through the MELSEC controller into the central fabric, so line-level detail finally reaches the business without a second network build.
Supervised setpoint writeback, safely scoped
Where explicitly scoped, Rayven writes a non-safety setpoint back to a MELSEC device under supervision and full audit. It never reprograms the controller and never writes to safety logic; the control and safety loops stay untouched.
Integration is the start with Rayven.
Here's what comes with it.
Rayven isn't just a Mitsubishi connector. It's the operational software platform underneath - so once Mitsubishi is connected, four more capabilities come online by default.
AI-ready data layer (AI Data Fabric)
Mitsubishi data joined with ERP, IoT + legacy - contextualised, unified and structured so AI models, agents and tools can use it without ETL prep work.
Learn more →
Live AI access (Rayven MCP)
Claude, ChatGPT + Gemini get live, governed access to Mitsubishi and every other connected system. Your AI stops guessing - cites real Mitsubishi records + numbers.
Learn more →
Automation + AI agents
Workflows + AI agents act on Mitsubishi data without human intervention - escalate at-risk accounts, trigger operational work, auto-update forecasts, draft customer comms.
Learn more →
Custom apps + portals
Unified customer portals, ops dashboards, mobile field apps, partner portals - built on top of integrated Mitsubishi data. No separate BI tool, no separate dev stack.
Learn more →
All on top of your existing stack. No rip + replace. Mitsubishi stays Mitsubishi. Rayven works on what you've already built. Specifically tuned for MELSEC SLMP device-code reads with CC-Link IE cell data surfaced.
Rayven is a five-layer platform ALL your integrations + much more
can run on.
Integration is one layer of Rayven. Data, execution, presentation + governance are the other four - all delivered as one platform on one commercial.
Pick the right tool for your stack.
Mitsubishi integration looks different at every scale. Honest comparison of the four common paths - Rayven only wins on some of them.
The integration is the easy bit.
The platform + team behind it is the difference.
Platform + team. One commercial.
Not five vendors stitched together. Rayven is the platform AND the Australia-based expert team that scopes, builds + supports it. One commercial. No licence stacking, no finger-pointing.
Built for the MELSEC device model.
Rayven reads MELSEC data registers, link devices and I/O over the SLMP and MC protocols for real-time sync, resolving device codes and word or bit addressing natively, with OPC-UA on iQ-R where fitted. Reads and contextualises only, never a write to safety logic.
We stay after go-live.
No handoff. No disappearing. Rayven is a long-term partner when your Mitsubishi evolves, your stack changes, or you push further. 24/7 support. Same team, same platform, same commercial.
Hosted your way, where you need.
Deploy as cloud, private cloud + on-premise - in Australia, the US, the UK, or anywhere else your Mitsubishi data needs to live. Your residency, your rules, your local compliance environment.
The questions Mitsubishi admins, RevOps + IT ask first.
If you're evaluating Rayven for Mitsubishi integration, these are the things worth knowing before booking a call.
The 30-minute call covers
- Your Mitsubishi + connected stack today
- What's reachable + which systems to bring in first
- Live walkthrough of Rayven against your scenario
- Time, scope + delivery estimate
- Honest read on whether Rayven's the right fit
What is Mitsubishi Electric PLC integration?
Mitsubishi Electric integration means reading device memory off MELSEC iQ-R, iQ-F, Q and L series PLCs and connecting it to ERP, CMMS and AI. Rayven delivers it as part of an Industrial AI Data Fabric, not a one-off SLMP script.
Does Rayven reprogram or control our MELSEC PLCs?
No. Rayven reads MELSEC device memory over SLMP and contextualises it. Supervised writeback is limited to explicitly-scoped non-safety setpoints and never touches safety logic or the control loop. See security, governance + hosting.
Can Rayven read MELSEC data without SCADA?
Yes. Rayven reads MELSEC devices directly over the SLMP or MC protocol or OPC-UA at the edge, so a line with no supervisory layer still reaches the enterprise. Where you run GENESIS64 or MC Works, see SCADA integration. Read more in how Rayven works.
What systems can Rayven connect Mitsubishi Electric to?
Rayven connects MELSEC to 1,228+ systems including ERP, historians, CMMS and sibling controllers like Omron and Keyence. Custom connectors are part of done-for-you delivery.
How long does Mitsubishi Electric PLC integration take with Rayven?
Most MELSEC integrations go live in 2-12 weeks. A single MELSEC-to-historian or fault-to-work-order flow runs in 2-3 weeks; a plant-wide fabric with OEE and predictive maintenance runs 6-12 weeks. Choose DIY, done-for-you or hybrid delivery.
MELSEC has an OPC-UA option. Why does Rayven add value on top?
The OPC-UA module exposes some devices; it does not join them to ERP and maintenance, hold history at rate or run AI. Rayven reads over SLMP and OPC-UA together, contextualises across lines and adds the analytics and agent layers on top - including CC-Link IE cell data. Read more in how Rayven works.
What are the technical specifics of Mitsubishi Electric PLC integration with Rayven?
Rayven reads Mitsubishi Electric MELSEC iQ-R, iQ-F, Q and L series controllers over the SLMP and MC protocols, and over OPC-UA on iQ-R where the module is fitted. Data registers, link registers, bit devices and I/O are read at the edge with device codes (D, M, X, Y, W), word and bit addressing and data types resolved, so raw device memory becomes named engineering-unit tags in the Industrial AI Data Fabric alongside historian, CMMS and ERP data. Device data riding CC-Link IE Field inside the cell is surfaced out through the controller to the enterprise. Rayven reads and contextualises only; supervised writeback covers explicitly-scoped non-safety setpoints and never writes to safety logic. Access is governed at the connector with full audit, deployed at the edge, on-premises or with sovereign hosting. Validated against iQ-R, iQ-F, Q and L series controllers across APAC discrete and process lines.
Mitsubishi + AI integration.
In weeks, not months.
Book a 30-minute call. Walk away with a tailored plan - what's reachable, what to bring in first, time + scope.