Siemens integration that reaches the systems other tools can't.
Connect Siemens SIMATIC S7 to your ERP, historian, maintenance + AI in real-time. Read S7 data blocks, tags and machine-state at the edge over OPC-UA, no SCADA required, without touching control logic.
+
Live demo · Claude querying Siemens + ops via Rayven MCP
Trusted by 240+ teams across Australia + globally
Siemens is brilliant at what it does. Useless at everything else your data + AI needs to touch.
Controls engineers export S7 tags by hand, the enterprise sees output a shift late, fault codes never reach maintenance, and AI models sit blind because live data-block state stays behind the S7 protocol.
The integration tool you've already tried probably can't fix it.
SaaS-to-SaaS. Useful, until it isn't.
Connectors for Siemens, Slack + a thousand other SaaS apps. Cheap + fast for the easy half of integration. Where they hit a wall:
- ERP that needs live production counts and machine-state context, not a shift-end file
- Historian and data-warehouse targets that should hold every S7 tag and register at full resolution
- CMMS that should raise a work order the moment an S7 fault code or downtime bit fires
- OEE and predictive-maintenance models that need live cycle counts, run states and fault history
- SCADA-less lines where S7 controllers run with no supervisory layer to expose the data
SCADA, historians, ERP, IoT + AI. One platform.
The integration platform built for what other tools can't (or won't) reach - plus an AI data fabric, MCP server + app builder layered on top.
- Siemens + every SCADA, historian and ERP system
- OPC-UA, EtherNet/IP, Modbus, PROFINET, S7 + custom-built connectors.
- Files, legacy SQL, FTP + custom-built connectors
- Real-time bidirectional sync, tier-aware + rate-limit-safe
- AI Data Fabric, MCP, automation + custom apps included
Siemens + Rayven: AI, automation + tools that reach every system you run.
5 examples of what Rayven customers run on Siemens + integrated systems. Built in weeks, not months.
S7 tags stream to the fabric
Rayven reads S7 data blocks, tags and I/O over the native S7 protocol and the embedded OPC-UA server, then streams them into a real-time Industrial AI Data Fabric alongside historian and ERP data. No manual export, no SCADA layer required.
Fault code raises the work order
A fault code or downtime bit on the S7 controller opens a work order in CMMS automatically, tagged with the asset, line and live machine-state so maintenance arrives with context, not guesswork.
Production counts post to ERP
Cycle counts, good and reject totals and run state read from S7 registers post to ERP in real-time, so planning and finance see actual output rather than a shift-end estimate.
OEE and predictive maintenance on live data
Machine state, cycle time and fault history stream into OEE and predictive-maintenance models. Rayven contextualises S7 data with vibration, temperature and energy signals to flag degradation before a line stops.
Supervised setpoint writeback, safely scoped
Where explicitly scoped, Rayven writes a non-safety setpoint back to the S7 controller under supervision and full audit. It never reprograms the PLC and never writes to safety logic; the control and safety loops stay untouched.
Integration is the start with Rayven.
Here's what comes with it.
Rayven isn't just a Siemens connector. It's the operational software platform underneath - so once Siemens is connected, four more capabilities come online by default.
AI-ready data layer (AI Data Fabric)
Siemens data joined with ERP, IoT + legacy - contextualised, unified and structured so AI models, agents and tools can use it without ETL prep work.
Learn more →
Live AI access (Rayven MCP)
Claude, ChatGPT + Gemini get live, governed access to Siemens and every other connected system. Your AI stops guessing - cites real Siemens records + numbers.
Learn more →
Automation + AI agents
Workflows + AI agents act on Siemens data without human intervention - escalate at-risk accounts, trigger operational work, auto-update forecasts, draft customer comms.
Learn more →
Custom apps + portals
Unified customer portals, ops dashboards, mobile field apps, partner portals - built on top of integrated Siemens data. No separate BI tool, no separate dev stack.
Learn more →
All on top of your existing stack. No rip + replace. Siemens stays Siemens. Rayven works on what you've already built. Specifically tuned for S7 optimised-data-block symbolic access and embedded OPC-UA tag reads.
Rayven is a five-layer platform ALL your integrations + much more
can run on.
Integration is one layer of Rayven. Data, execution, presentation + governance are the other four - all delivered as one platform on one commercial.
Pick the right tool for your stack.
Siemens integration looks different at every scale. Honest comparison of the four common paths - Rayven only wins on some of them.
The integration is the easy bit.
The platform + team behind it is the difference.
Platform + team. One commercial.
Not five vendors stitched together. Rayven is the platform AND the Australia-based expert team that scopes, builds + supports it. One commercial. No licence stacking, no finger-pointing.
Built for the S7 data-block model.
Rayven reads S7 data blocks, tags and I/O over the native S7 protocol and the embedded OPC-UA server, including optimised-DB symbolic access, for real-time sync. Legacy S7-300/400 racks read through classic S7 addressing - reads and contextualises only, never a write to safety logic.
We stay after go-live.
No handoff. No disappearing. Rayven is a long-term partner when your Siemens evolves, your stack changes, or you push further. 24/7 support. Same team, same platform, same commercial.
Hosted your way, where you need.
Deploy as cloud, private cloud + on-premise - in Australia, the US, the UK, or anywhere else your Siemens data needs to live. Your residency, your rules, your local compliance environment.
The questions Siemens admins, RevOps + IT ask first.
If you're evaluating Rayven for Siemens integration, these are the things worth knowing before booking a call.
The 30-minute call covers
- Your Siemens + connected stack today
- What's reachable + which systems to bring in first
- Live walkthrough of Rayven against your scenario
- Time, scope + delivery estimate
- Honest read on whether Rayven's the right fit
What is Siemens PLC integration?
Siemens PLC integration is the practice of reading controller data - data blocks, tags, I/O and fault codes - off SIMATIC S7 PLCs and connecting it to ERP, CMMS and AI. Rayven delivers it as part of an Industrial AI Data Fabric, not a one-off gateway script.
Does Rayven reprogram or control our Siemens PLCs?
No. Rayven reads S7 data and contextualises it. Supervised writeback is limited to explicitly-scoped non-safety setpoints and never touches safety (F) logic or the control loop. See security, governance + hosting for the access and audit model.
Can Rayven read Siemens S7 data without SCADA?
Yes. Rayven reads S7 data blocks and tags directly over the S7 protocol or the embedded OPC-UA server at the edge, so a line with no supervisory layer still reaches the enterprise. Where you run WinCC, see SCADA integration for the supervisory story. Read more in how Rayven works.
What systems can Rayven connect Siemens to?
Rayven connects Siemens S7 to 1,228+ systems including ERP, historians, CMMS and sibling controllers like Allen-Bradley and Schneider Electric. Custom connectors are part of done-for-you delivery.
How long does Siemens PLC integration take with Rayven?
Most Siemens integrations go live in 2-12 weeks. A single S7-to-historian or fault-to-work-order flow runs in 2-3 weeks; a plant-wide fabric with OEE and predictive maintenance runs 6-12 weeks. Choose DIY, done-for-you or hybrid delivery.
S7-1500 has an embedded OPC-UA server. Why does Rayven add value on top?
The embedded OPC-UA server exposes tags; it does not contextualise, store or act on them. Rayven adds the real-time fabric, the historian and ERP joins, OEE and predictive-maintenance models and the AI and agent layers on top - including legacy S7-300/400 that has no OPC-UA at all. Read more in how Rayven works.
What are the technical specifics of Siemens PLC integration with Rayven?
Rayven reads Siemens SIMATIC S7 data over the native S7 communication protocol and the S7-1500/S7-1200 embedded OPC-UA server, with PROFINET and PROFIBUS device data picked up at the edge. Data blocks, tags, markers, I/O and machine-state values are polled or subscribed at the controller and mapped field by field into an Industrial AI Data Fabric alongside historian, CMMS and ERP data. Legacy S7-300 and S7-400 racks read through classic S7 addressing with no firmware change. Rayven reads and contextualises only; supervised writeback is available for explicitly-scoped non-safety setpoints, and it never reprograms or writes to safety logic. Authentication uses OPC-UA certificates and signed sessions, or protected S7 connections where configured. Deployed at the edge, on-premises or with sovereign hosting. Validated against S7-1500, S7-1200 and legacy S7-300/400 controllers feeding OEE and predictive-maintenance analytics.
Siemens + AI integration.
In weeks, not months.
Book a 30-minute call. Walk away with a tailored plan - what's reachable, what to bring in first, time + scope.